Tolerance ±1% of the declared value. Certificates traceable to SRM from NIST. With variation table of conductivity / temperature on the label. Use within 12 months of opening (6 months for COSS-10U-500)
Conductivity electrodes with temperature compensation to be used with COMT-M51-001 or COMT-M52-001. Dimensions 120 x 12 mm, BNC conection with 1 m cable length. K = 1: conductivity values (0 – 150 mS/cm), temperature range (0 – 100°C). General purpose, plate material: platinum K = 10: conductivity values (0 – 500 mS/cm), temperature range (0 – 100°C). For high conductivity solutions, plate material: carbon K = 0,1: conductivity values (0 – 500 µS/cm), temperature range (0 – 50°C). For pure water, plate material: platinum
Portable conductivity meter with automatic temperature compensation (between 0 and 105 °C). Conductivity measuring ranges 10,00 to 20, 200, 2000,00 µS/cm, 20.00 mS/cm, accuracy ± 0.5%. Expandable to conductivity range 10.00 µS/cm – 200.0 mS/cm, accuracy ± 0.5% with COEL-P0H-001 (K = 10, for measurements 20 mS/cm) and to conductivity range 0.01 µS/cm – 20.00 mS/cm, accuracy ± 0.5% with COEL-G0L-001 (K = 0,1, for measurements 10 µS/cm). Calibration of 1 to 3 points with automatic recognition of 5 conductivity standards: 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and 111.8 mS/cm. Backlit LCD screen. Stable measurement indication and auto-off function. Storage memory of 100 records. Calibration alarm from 1 to 31 days. Selectable constant K (0.1 – 1 – 10) and linear temperature coefficient. Power supply 3×1,5V AA batteries (not included) or DC5V adapter (not included). Includes standard solutions 84 µS/cm, 1413 µS/cm and 12.88 mS/cm (solutions do not include certificate), conductivity electrode K = 1 (COEL-P0S-001) and temperature sensor. 2 year warranty
For general laboratory uses and measurements that require greater precision in liquids and non-aqueous solutions, aggressive samples. Resists poisoning and fouling. Reference element Ag/AgCI, non refillable electrolyte and porous teflon diaphragm. pH range 0 – 14, maximum service temperature 130 °C. Dimensions: 120 x 12 mm. Available with BNC connection and 1 m cable, and two types of ATC probe connections: 10K/3.5mm Jack for METRIA meters and 30K/CINCH for XS and Mettler-Toledo
Plastic body (epoxy), specially designed for general use. Reference element Ag/AgCI, gel non refillable electrolyte and porous teflon diaphragm. pH range 0 – 14, maximum service temperature 100°C. Dimensions: 120 x 12 mm. Available with BNC connection and 1 m cable, and two types of ATC probe connections: 10K/3.5mm Jack for METRIA meters and 30K/CINCH for XS, Mettler-Toledo, FISHER and VWR meters
Plastic body (epoxy), specially designed for general use in portable pH meters. Reference element Ag/AgCI, gel non refillable electrolyte and porous teflon diaphragm. pH range 0 … 14, maximum service temperature 80 ºC. Dimensions: 120 x 12 mm. Available with two types of connections: BNC connector with fixed cable (length: 1 m) or S7 connector (delivery without connecting cable, please order separately)
Desktop conductivity meter with manual or automatic temperature compensation (between 0 and 99 ºC). Available ranges (range is automatically chosen): 0,0 – 200,0 ?S/cm, 200,0 – 2000 ?S/cm, 2,00 – 20,00 mS/cm, 20,0 – 200,0 mS/cm, accuracy ±1 % full scale. Automatic and manual calibration with automatic recognition of 4 conductivity solutions: 84, 1413 mS / cm and 12.88, 111.8 mS / cm. Stable measurement indication. Includes sensor support, two buffer solutions and conductivity cell with integrated temperature sensor (K=0,1 – 1,0 – 10,0 selectable). Keypad resistant to water, bases and acids splashes. Backlit LCD. Warranty 3 years. Delivery 1 week
Portable conductivity meter with automatic and manual temperature compensation. Range: 0 – 19.99 ?S/cm, 0 – 199.9 ?S/cm, 200 – 1999 ?S/cm, 2.00 – 199.9 mS/cmAutomatic calibration in 5 points (84, 147, 1413 ?S/cm, 12.88 y 111 mS/cm) and manual calibration in 5 points. Includes transportation case, rubber case, two buffer solutions and conductivity cell for general use (K=1) with automatic temperature compesation. Warranty 3 years. Delivery 1 week
Compact Conductivity meter with interchangeable cell and automatic temperature compensation (0 – 50 ºC). Conductivity range according to model: 1,0 – 199.9 ?S/cm, 10 – 1999 ?S/cm or 0,1 – 19.99 mS/cm, accuracy ±1% F.S. (full scale). Single point calibration. Auto-power off feature helps you effectively conserve battery life. Water-tight. Warranty 1 year
Range: 10 to 1990 µS/cm, res.: 10 µS/cm and accuracy ±2% full scale. Single point manual calibration. Automatic temperature compensation from +5 up to +50 ºC. Built in a one-piece casing. Battery type: 4 x 1.5V LR44 (included). Dimensions: 150 x 30 x 24 mm, weight 85 g
Specially designed for high temperature measurements and for industrial pipeline. Reference element Ag/AgCI, gel non refillable electrolyte and double teflon diaphragm. pH range 0 … 14, maximum service temperature 130 ºC. Dimensions: 120 x 12 mm. Fixed cable 1 m long with BNC connector
Glass body electrode, specially designed for measuring pH in very small sample volumes or narrow vessels. Reference element Ag/AgCI, liquid refillable electrolyte (3M KCl/AgCl) and frit ceramic diaphragm. pH range 0 … 14, maximum service temperature 80 ºC. Stem dimensions: 90 x 4,5 mm. Fixed cable 1 m long with BNC connector
For general use and high accuracy measurements in liquids and non aqueous samples. Reference element Ag/AgCI, liquid refillable electrolyte (3M KCl/AgCl) and double ceramic diaphragm. pH range 0 … 14, maximum service temperature 80 ºC. Dimensions: 120 x 12 mm. Fixed cable 1 m long with BNC connector
Plastic body (epoxy), specially designed for general use in portable pH meters and also for industrial uses. Reference element Ag/AgCI, gel non refillable electrolyte and double porous teflon diaphragm. pH range 0 … 14, maximum service temperature 80 ºC. Dimensiones: 120 x 12 mm. Fixed cable 1 m long with BNC connector